37-8305
AS certificate. Capacities 2 tonnes to 1000 tonnes <±0.1% Accuracy Sealed to IP65 Robust Construction Submersible Version Available Competitively Priced The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions. Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.You can only add up to 50 products to your wishlist at a time.
Category: Concrete
Sub Category: Compression Machines Accessories
Product Group: Calibration Devices
Complete with Hand Held Readout Unit & traceable certificate (not calibrated to UKAS standards). Upon receipt, customer may calibrate to NIST or other standard.
The 0.1% accuracy series of column compression load cells are designed for use as reference standards for the calibration of other load cells or in high capacity weighing applications, where precise measurement and high accuracy is of utmost performance. Their simple column design and sealed construction assures excellent resistance in the most arduous conditions.
Applications: Reference standards, high capacity weighing applications, silo weighing, pile force measurement, heavy duty jack levelling systems, press calibration, centre of gravity (CoG) measurement systems and high capacity multi-point weighing systems.
Description | 300 kN Load Calibration Device Complete with Hand Held Readout Unit & Cal Cert to UKAS traceable |
Capacity | 30 tonnes |
Output | 2.0m V/V (nominal) |
Total accuracy | <+- 0.10 of rated output |
Environmental protection | IP65 |
Electrical connection | 4m PUR cable |
Operating temperature range | -20 to +70 deg C |
Compensated temperature range | -10 to +50 deg C |
Supply voltage | 10v recommended 15v max |
Operating mode | Compression |