website-logo

39-1600/06

Humidity Cabinet BS EN 150 Litre Capacity 60Hz

Category: Mixing, Moulding, Curing and Strength

Sub Category: Curing

Product Group: Humidity Cabinet BS EN

  • Micro-processer controller for temperature and humidity for precise and reliable control
  • Stainless Steel interior with adjustable shelves
  • CFC-free polyurethane insulation to provide efficient thermal stability
  • 12mm access port

Prior to testing, EN 196 requires prisms to be cured for a period of at least 24 hours at 20 ±1ºC, 90 % RH minimum. The prisms are then de-moulded and stored under water for the required curing time, usually 48 hours, 72 hours, 7 and 28 days.

The Humidity Cabinet is built to a high specification and is designed for the early curing of mortar prisms prior to storing under water. Relative humidity up to 98%.

Please note 39-1300/24 Digital Recorder is optional, but must be ordered with the cabinet so they may be calibrated together.

Description         Humidity Cabinet
Capacity, litres         150
Voltage Supply         220 - 240 V AC, 60 Hz, 1 ph

Specifications

Temperature Range +5 °C to 60 °C
Temperature Control 0.2 °C at 20°C
Temperature Variation ± 0.5 °C at 20°C
Humidity Range 0-98%
External Dimensions (mm) 1075 × 635 × 660 
Internal Dimensions (mm) 590 × 510 × 490
Shelves 4 Shelves hold 6 x 39-1100 moulds
Shelf Capacity 15 kg
Input Power 800 Watt
Weight 100 kg
  • •  Data Logger for Humidity Cabinet to EN 196 320 Litre capacity